Hitachi

Model ADA*-
item, unit
R5MS 01MS 02MS 04MS R5LS 01LS 02LS 04LS 08LS 10LS 15LS 20LS 30LS 50LS
basic Specifications Applicable motor capacity (kW) 0.05 0.1 0.2 0.4 0.05 0.1 0.2 0.4 0.75 1.0 1.5 2.0 3.0 5.0
Input power phase Single/Three-phase Three phase (Earthed neutral)
Input power supply (main circuit) 100~115V +10%-15%
50/60Hz ±5%
200~230V + 10%-15% 50/60Hz±5%
Input control power supply 100~115V +10%-15%
50/60Hz ±5%
200~230V + 10%-15% 50/60Hz±5%
Rated speed (min-1) 3000 3000
Maximum speed (min-1) 4,500 5000
Maximum torque (Ratio to the rated torque) 300%
Protective structure *1 Open type IP00
Control system Sine-wave pulse width modulation PWM system
Conrol mode Position control/speed control/torque control
Position/speed feedback 17 bits/rotation Incremental encoder (standard)
17bits/rotation Absolute encoder (option)
Speed control range 1 : 4500 1 : 5000
Input/output related functions Speed command/
limitation input
Analog input: 0 to ± 10V/Maximum speed (settable)
Torque command/
limitation input
Analog input: 0 to ± 10V/Maximum torque (settable)
Position command input *4 Line driver signal (2M pulses/s or less)/open collector signal (200 k pulses/s or less) input
1) Phase difference pulse input (Maximum input frequency is 1/4 of the value above noted)
2) Forward/reverse run direction pulse input
3) Comand pulse + code input (selectable)
Input signal Contact signal/open collector signal input (internal DC 24 V power supply available)
Servo ON, Alarm reset, Control mode switch, Torque limit, Forward overtravel, Reverse overtravel, Multistage speed 1, Multistage speed 2, Proportional control, Zero speed clamp, Homing limit switch, Homing, Pulse train input enable, Position error clear
Output signal Open collector signal output : Servo ready, Alarm, Positioning complete, Up to speed, Zero speed detection, Brake release (servo ON answer), Torque limiting, Overload notice
Encoder monitor signal output Phase A, B signal output : Line driver signal output (output resolution settable)
Phaze Z signal output : Line driver signal output/open collector signal output
Monitor output 2 ch, 0 to ± 3 V Voltage output, Speed detection value, Torque command, etc. (selectable)
Internal functions Built-in operator 5-digit number display unit, key input×5
External operator Windows® 95/98/Me, Windows® NT/2000 PC connectable (using the RS-232C port)
Regenerative braking circuit Built-in type (Braking resistor : option)
Dynamic brake Actuated at Servo OFF, Trip, or Power OFF (operating condition settable)
Protective function Overcurrent, overload, braking resistor overload, main power overvoltage, memory error, main power undervoltage, CT error, CPU error, ground fault, control power undervoltage, power module error, encoder error, position error, speed error, overspeed error, driving range error, position monitoring timeout error, overtravel error, abnormal temperature, absolute encoder error, absolute encoder battery alarm/error, absolute encoder counter overflow, motor power unmach
Operating environment Ambient temperature/storage temperature *2 0 to +55°C/-10 to +70°C
Humidity 20 to 90%RH or less (without condensation)
Vibration *3 5.9 m/s2 (0.6G), 10 to 55 Hz
Installation location 1000m or less above the sea, indoor place (free from corrosive gas and dust)
Estimated weight (kg) 0.8 0.8 1.0 1.4 0.8 0.8 0.8 1.0 1.4 1.9 1.9 4.6 4.6 7.7

Note

*1
The protective structure conforms to JEM1030.
*2
The storage temperature is the short-term temperature during transport.
*3
The testing method of JIS C0040 is applied.
*4
When the phase difference pulse input is selected, set the signal input speed to 125k pulses/s or less for line driver /50k pulses/s or less for open collector.

Information in this sheet is subject to change for improvement without notice.