1-phase 230V / 3-phase 200V, 3-phase 400V
Model ADA3- item, unit |
01NSE | 02NSE | 04NSE | 08NSE | 15HPE | 35HPE | 70HPE | ||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
Applicable motor capacity (kW) | 0.1 | 0.2 | 0.4 | 0.75 | 0.5 | 1.0 | 1.5 | 2.0 | 3.5 | 4.5 | 5.5 | 7.0 |
Input power phase | Single/Three-phase | Three phase | |||||||||||
Input power supply (main circuit) | 1 × 220 to 230V/3 × 200 to 230V+10%, -15% 50/60Hz ± 5% |
3 × 380 to 480V +10%, -15% 50/60Hz ± 5% |
|||||||||||
Input control power supply | 1 × 200 to 230V +10%, -15% 50/60Hz ± 5% | 1 × 200 to 240V +10%, -15% 50/60Hz ± 5% | |||||||||||
Rated speed (min-1) | 3000 | 2000 | |||||||||||
Maximum speed (min-1) | 4500 | 3000 | |||||||||||
Maximum torque (Ratio to the rated torque [%] ) | 300 | 375 | 370 | 266 | 314 | 272 | 326 | 274 | 257 | ||||
Protective struct ure *1 | Open type IP00 | ||||||||||||
Control system | Sine-wave pulse width modulation PWM system | ||||||||||||
Conrol mode | Position control/speed control/torque control | ||||||||||||
Position/speed feedback | 17 bits/rotation Incremental encoder (standard) 17 bits/rotation Absolute encoder (option) |
Incremental encoder (500~65535ppr) Absolute encoder (Serial output) |
|||||||||||
Speed control range | 1 : 4500 | 1 : 3000 | |||||||||||
![]() |
Speed command/ limitation input |
Analog input: 0 to ± 10V/Maximum speed (gain settable) | |||||||||||
Torque command/ limitation input |
Analog input: 0 to ± 10V/Maximum torque (gain settable) | ||||||||||||
Position command input *4 | Line driver signal (2M pulses/s or less)/open collector signal (200 k pulses/s or less) input 1) Phase difference pulse input (Maximum input frequency is 1/4 of the value above noted) 2) Forward/reverse run direction pulse input 3) Comand pulse + code input (selectable) |
||||||||||||
Input signal | Contact signal Servo ON, Alarm reset, Control mode switch, Torque limit, Forward overtravel, Reverse overtravel, Multistage speed 1, Multistage speed 2, Proportional control, Zero speed clamp, Homing limit switch, Homing, Pulse train input enable, Position error clear | ||||||||||||
Output signal | Open collector signal output : Servo ready, Alarm, Positioning complete, Up to speed, Zero speed detection, Brake release (servo ON answer), Torque limiting, Overload notice | ||||||||||||
Encoder monitor signal output | Phase A, B signal output : Line driver signal output (output resolution settable) Phaze Z signal output : Line driver signal output/open collector signal output |
||||||||||||
Monitor output | 2 ch, 0 to ± 3 V Voltage output, Speed detection value, Torque command, etc. (selectable) | ||||||||||||
![]() |
Built-in operator | 5-digit number display unit, key input×5 | |||||||||||
External operator | Windows® 95/98/Me, Windows® NT/2000 PC connectable (using the RS-232C port) | ||||||||||||
Regenerative braking circuit | Built-in type (Braking resistor : option) | ||||||||||||
Dynamic brake | Actuated at Servo OFF, Trip, or Power OFF (operating condition settable) | ||||||||||||
Protective function | Overcurrent, overload, braking resistor overload, main power overvoltage, memory error, main power undervoltage, CT error, CPU error, ground fault, control power undervoltage, power module error, encoder error, position error, speed error, overspeed error, driving range error, position monitoring timeout error, overtravel error, abnormal temperature, absolute encoder error, absolute encoder battery alarm/error, absolute encoder counter overflow, motor power unmach | ||||||||||||
![]() |
Ambient temperature/storage temperature *2 | 0 to +55°C/-10 to +70°C | |||||||||||
Humidity | 20 to 90%RH or less (without condensation) | ||||||||||||
Vibration *3 | 5.9 m/s2 (0.6G), 10 to 55 Hz | ||||||||||||
Installation location | 1000m or less above the sea, indoor place (free from corrosive gas and dust) | ||||||||||||
Estimated weight (kg) | 0.9 | 0.9 | 1.4 | 1.9 | 1.9 | 4.6 | 7.7 |
Note